What are the indicators of factors affecting the efficiency of the steam boiler hot water heater gas and electric Shandong? State basically in full swing during the move from coal to natural gas, hot water boiler with greatly minus the fine dust contamination, together with nitrogen oxides and other harmful gas emissions have been manipulated. Power is an important goal of measuring target hot water boiler, give you a look behind the cause of a direct impact on several hot water boiler power targets. By examining the relevant departments, and hot water boilers consume more important from these two local: the burning air-fuel ratio unqualified and heat loss. Possible to decrease heat loss can be recycled at the end of the formation of the latent heat of flue gas hot water boiler assembly, or with more kinds of class condensing boiler. Burning fuel ratio unqualified inappropriate Summary: General hot water boiler according ejector incinerator machine, causing air-fuel ratio can not be flexibly adjusted. 70% of the hot water boiler is a mechanical blower according burning machine, leading to substandard fuel ratio has the following several reasons: the more important fuel ratio failure probability can be divided into two types: When oxygen is overrun, there will not be excessive cold air is heat, hot water boiler power lead to the use of improved hot water boiler output target weakened; when oxygen is non-compliant, there will be insufficient burning phenomenon, showing a hot water boiler output target weakened. Shandong gas boiler steam boiler talked about how sewage? (1) inside open blowdown valve; (2) gradually open the blowdown valve external to warm up and sewage pipes; (3) an external switch repeatedly discharge water valve, slow flush pan scale , so that as the scale is discharged; (4) locking the inner blowdown valve, between these two discharge water storage water drain valve; (5) locking the outer blowdown valve, sewage terminated. When the people usually use gas steam boiler, power outage situation is obviously occurs when there is, admittedly now very small probability of occurrence of a power outage, What, then the people can not ignore this kind of situation may occur. The author taught the people, process knowledge this type of situation from occurring. First, after the power outage, the total mass to quickly lock steam boiler gas valve, this kind of boiler is to avoid the effect of leaking. Second, the next step is to lock the main switch valve with various natural gas steam boiler circuit. Third, locking gas steam boiler slag coherent various water discharge valve block, otherwise will probably cause additional problems of a coherent gas steam boiler. Fourth, to lock the various air intake valve deaerator. Fifth, the above outline done, in accordance with the order of daily occurrence to stop using the shutdown to manipulate, and verify that the volume of water in the furnace, gas and other energy corresponding to the description. Power outages may now be able to basically be able to say that very little gas steam generating boiler work, What, then public still can not completely avoid this kind of situation, which also requires manipulation of the masses of standard rules of this kind of situation occurred after carefully , as if such a situation occurs, etc. without question.
Atmospheric gas hot water boiler hot water heater gas and electric several parallel operation policy in general, for a single heat atmospheric gas hot water boiler is relatively small, in order to meet the large heat load operating conditions, you need to run more than one parallel, then the two Taiwan atmospheric gas hot water boiler Weili, a simple energy-saving operation policy resolution. (1) temperature is below the water pipe network two temperature control curve setting value, to ensure a water supply pipe network without changing the temperature, by increasing the flow rate of a network to increase the heat supply until the electric control It is increased relative to the valve opening degree of 100%. In this process, by increasing the heating capacity of each atmospheric gas hot water boiler to meet heating needs. (2) Conversely, if the water temperature exceeds the pipe network two thermostat setpoint curve, at a constant temperature of the water pipe network of the premise, to reduce network traffic by reducing a heat supply pipe, in which the case, each sub-volume pressure hot water boiler heating by reducing the heat input per gas hot water boiler pressure and thus reduce the temperature of the water pipe network two. (3) When a plurality of atmospheric gas hot water boiler select start and stop the object by running the length of the cumulative duration is determined, the accumulated run time of the shortest atmospheric gas hot water boiler startup priority. In short, during the development of atmospheric gas hot water boiler operation strategy of several parallel, taking into account the issue of energy-efficient operation, during which the comparative analysis to be certain, and merit-based election.
Recently, Changzhi City, Shanxi Province have continued to improve as strongly promote the city's ambient air quality, issued the "Changzhi City, 2018--2019 autumn and winter tackling air pollution comprehensive management action plan" (hereinafter referred to as the "Program"), to take specific measures to 10 31 categories of air pollution comprehensive management.
"Plan" put forward, we will accelerate the adjustment of energy structure in the consolidation of ambient air quality improved results, adhere to progress while maintaining stability, promoting the city's air quality continues to improve.
2020 in accordance with the basic completion of the plains heating pre-season and winter heating coal-life alternative tasks required to develop a three-year implementation program to determine the annual coal task of governance. Husband and actively promote the use of solar energy centralized biomass priority to promoting the bulk coal governance of the main city and the plains surrounding county, the gas will adhere to the reform, in order to set the electrical change, has started in 2017 to protect the "coal to gas "" coal to electricity "project on the basis of reasonably determine this year's" coal to gas "," the number of coal to electricity "project. When the substitution of gas for coal, electricity instead of coal and other alternative methods, the gas source, the power to implement, the existing heating facilities can not be removed.
1, increase efforts to eliminate small coal-fired boilers and furnaces tea, operating farmhouse, drying equipment and other reserves of coal-fired facilities (collectively referred to as coal-fired boilers); and speed up the construction of centralized heating official website, giving priority to the use of combined heat and power production units and other clean heating in the heating mode out of the coverage of the official website of coal-fired boilers.
2, actively promote the 65 steam tons / hour or more coal-fired boilers built-up areas and urban transformation of raw material ultra-low emission boilers, coal-fired plants to achieve ultra-low emissions levels. Biomass boilers should be dedicated boiler, ban coal blended with other fuels, be equipped with efficient dust bags and other facilities.
3, accelerate the transformation of low nitrogen gas boiler NOx emission after the transformation in principle not exceed 50 mg / cubic meter, to encourage the implementation of 30 mg / cubic meter of lower standards.
1, a comprehensive investigation of the use of industrial furnaces, iron and steel, nonferrous metals, building materials, coking, chemical industry, focusing on the smelting furnace, melting furnace, sintering machine (oven), baked (calcined) burning furnace, heating furnace, drying furnace class 9 kinds furnace (kiln), coke oven, gas furnace or the like, to carry out an intensive investigation. And build on November 10, 2018 detailed inventory management, after 15 November 2018 are not included in the list of industrial furnaces management, fully integrated into the autumn and winter peak load shifting production program, implementation of the cut.
2, accelerate the clean fuel substitute, coal, petroleum coke, residual oil, heavy oil as the fuel of a heating furnace, heat treatment furnace, a drying furnace (kiln), and accelerate the use of clean energy and the use of plant waste heat, thermal power plants and the like instead.
The electric boiler hot water heater gas and electric, also known as the electric water boiler, the electric drinking water boiler, the electric tea boiler, and the electric tea stove, is divided into two types: continuous electric water boiler and split tank electric water boiler, which are designed to meet the needs of more people drinking boiled water. A kind of drinking water equipment using electric energy to produce hot water is developed, which is mainly suitable for the use of schools, hospitals, factories, supermarkets, shopping malls and other population-intensive units. The main component of the electric water heater is the electric heating tube which plays the role of heating. It is better to choose the electric heating tube with insulating material, which has high safety factor and long service life. Under normal conditions, it can work for 6-7 years. The electric hot water boiler is also called the electric heating boiler, the electric bath boiler, etc. The electric hot water boiler is the production hot water that adopts the latest electric heating technology and the control system design, satisfies the heating or the supply life, Fully automatic environmental protection boiler of hot water for bath. This kind of boiler is suitable for hot water and heating in hotels, villas, factory buildings, office buildings, government agencies, colleges and universities, hospitals, troops and other places with high appearance requirements. The electric boiler is divided into two types: direct heating type electric boiler and regenerative type electric boiler. As the name implies, the direct heat type electric boiler is no longer explained here, and the regenerative type electric boiler is based on The power sector encourages electricity heating during trough periods and enjoys preferential electricity prices, introducing a new, efficient and energy-efficient electric heating product. Regenerative type electric boiler is composed of heat storage water tank and auxiliary equipment, which makes use of hot water heating in heat storage tank to achieve the goal of using all or part of the low valley power from the purpose of making use of the hot water in the heat storage tank. Electric steam boiler is also called electric steam boiler. Electric steam boiler is a steam boiler which uses power source to heat and produce rated pressure. Steam boilers can be used in textile, printing and dyeing, paper making, food, rubber, plastics, chemical, pharmaceutical, iron and steel, metallurgy and other industrial products processing process Steam is required and can be used for heating, bathing, air conditioning and hot water in enterprises, institutions, hotels, schools, catering, and service industries.
01. The reason why the ignition rod of gas-fired boiler burner does not ignite: 1. There is carbon slag in the gap of the ignition rod, there is oil pollution. 2, the ignition rod is cracked. Damp. Leakage. 3. The distance between the ignition rod is not right, too long or short. 4, the distance between the ignition rod is not right, it is too long or short. 4. Ignition rod insulation outer skin is damaged, short circuit to the ground. 5, ignition cable and transformer failure: cable broken, connector damage caused by short circuit fire; The transformer is out of line or out of order. Gas-fired boiler burners failure, ignition rod non-ignition treatment measures are as follows: clear, replace, adjust distance, change wire, change transformer. Second, the reason why the ignition rod of the gas-fired boiler has sparks but does not ignite: 1. The ventilation clearance of the cyclone disc is blocked by carbon deposition and the ventilation is poor. 2, the oil nozzles are unclean, clogged or worn. 3, the setting angle of the air door is too small. 4, the distance between the tip of the ignition rod and the leading edge of the oil nozzle is inappropriate (too prominent or indented) 5, The solenoid valve of the first oil gun is blocked by debris (small fire gun) .6, the oil quality is too viscous to flow or the filtration system is clogged or the oil valve is not opened, which causes the oil pump to absorb insufficient oil, the oil pressure is low. 7, the filter of the pump itself is blocked. 8, Oil contains more water (boiling noise in heater). The measures to deal with spark but not ignition of ignition rod of gas-fired boiler are as follows: clearing; cleaning first, if no replacement; adjusting test; adjusting distance (3~4mm is good); remove cleaning (cleaning parts with diesel); check pipes and oil filters, insulation equipment; remove oil pump outer screws, carefully remove the outer cover and remove the inside net, wash with diesel; replace it with new oil. Third, when a small fire of a gas-fired boiler is turned into a fire, the reasons for its extinction or flickering instability are as follows: (1) the air volume of the air outlet of the fire is set too large. 2, The oil valve fretting switch (the outermost group) of the fire is improperly set (set higher than the air flow of the fire valve) .3, the viscosity of the oil is too high and not easy to atomize (heavy oil). 4, the distance between the cyclone disc and the nozzle is inappropriate. 5, To wear or soiled the nozzles of a fire. 6.The heating temperature of the reserve oil tank is too high, causing the steam to cause the oil pump to send oil unsmoothly. 7, the oil in the burning oil and gas hot water boiler contains water. Treatment measures to extinguish or flicker unstable when small fire of gas-fired boiler turns to fire normally: reduce test step by step; raise heating temperature; adjust distance (between 0~10mm); clean or replace; set about 50 ℃ or so; change oil or drain water. 4. Causes of noise increase in gas boiler burners: 1, shut-off valve or insufficient oil intake in the oil path, blocking of oil filter. 2, low inlet temperature, too high viscosity or too high intake temperature of pump. 3, oil pump failure. 4, oil filter blocking. 4, oil inlet temperature is low, viscosity is too high or pump inlet temperature is too high. 3. Fan motor bearing Damage. 5, fan impeller is too dirty. Treatment method for increasing noise of Burner in Gas-fired Boiler: (1) check whether the valve in the pipeline is open or not, and the oil filter is working normally. Cleaning pump itself filter screen. 2 oil heating or lowering oil temperature. 3 replacement pump. 4 replacement motor or bearing. 5 cleaning fan impeller.
01: the greatest benefit of economic use of gas-fired steam boilers is that they can save large amounts of material costs for enterprise users, without the need to spend heavy money on large amounts of coal-carbon fuel. Only clean natural gas can be used to burn and release the steam used. Natural gas can also increase the thermal effect and reduce the cost of material input for users. Safety: natural gas is well known as one of the safest non-toxic and pollution-free clean fuels, unlike liquefied gas or gas leaks that precipitate on the ground and even cause accidents. Gas-fired steam boiler is the safest way to choose natural gas in the process of transporting gas, and it is easy to leak. Being found to be used is therefore the safest way to use it. 3: the convenient gas-fired steam boiler is also the most convenient one in use, so it will be favored by the customers of various enterprises. Natural gas pipelines are as convenient as tap water for domestic use, and sustainable use will not be bothering you. It eliminates the cumbersome work such as transporting or stacking coal and cleaning coal residue. 4: clean gas-fired steam boilers are highly rated in the market because they are clean and clean in use and free of black pot bottom and exhaust gas pollution. So it's cleaner than any other boiler in use. One way, whether directed at operational work or surrounding residents or the business itself, can be cleaner without compromising physical and mental health.
[email protected]